Fire Fighting & Life Safety · Oman

Fire Safety Services

Technical support that keeps life-safety systems inspected, maintained, documented and ready for operation.

Engineered for Oman

A complete, coordinated approach to fire safety services.

PROOM supports clients from initial consultation and site review through engineering, supply, installation, integration, testing, commissioning and ongoing technical support. The final scope is defined around verified project requirements and site conditions.

01Risk-led system design
02Coordinated emergency response
03Clear testing and commissioning
04Long-term maintenance readiness
Key capabilities

System scope

  • 01Site assessment
  • 02System inspection
  • 03Testing
  • 04Maintenance
  • 05Upgrading
  • 06Technical consultation
  • 07Documentation support
  • 08Annual Maintenance Contracts
Typical applications

Designed around the facility.

Applications are assessed according to occupancy, operating risk, performance objectives, existing infrastructure and required interfaces.

Government facilities↗
Commercial buildings↗
Hospitality↗
Healthcare↗
Industrial facilities↗
Residential developments↗
System integration

Connected with the wider building environment.

Where required, PROOM coordinates interfaces with fire alarm, BMS, CCTV, access control, public address, HVAC, parking, hotel systems, IoT platforms and central monitoring. Final integration depends on the project design and supported system interfaces.

Delivery process

From scope to support.

  1. 01
    Consultation & site survey

    We understand the facility, risks, scope and operating requirements.

  2. 02
    Engineering & design

    We develop coordinated system concepts and technical specifications.

  3. 03
    Proposal & planning

    We align scope, resources, sequencing and commercial requirements.

  4. 04
    Supply & installation

    Our teams deliver and coordinate equipment and site works.

  5. 05
    Testing & commissioning

    We verify operation, interfaces and documented system performance.

  6. 06
    Maintenance & support

    We help protect reliability through planned and responsive support.

Maintenance & FAQs

Supporting performance beyond installation.

Can PROOM assess an existing system?+

Yes. PROOM can review available documentation, inspect site conditions and identify practical maintenance, integration, upgrade or retrofit requirements.

Can this system integrate with other building services?+

Integration is planned according to project needs, compatible interfaces and the approved cause-and-effect or control strategy.

Is maintenance support available?+

PROOM provides preventive and corrective maintenance, testing, inspections, system health checks, upgrades and Annual Maintenance Contract options.

Authorized Distribution & Engineering Supply · Sultanate of Oman

LIFECO UK · Certified Fire & Life Safety Systems

PROOM is the authorized engineering distributor for LIFECO (UK) in Oman. All equipment is factory-certified, fully supported with project submittal packages, datasheets, and compliance documentation for Oman Civil Defence (CDAA) approvals.

UL ListedUL Listed
FM ApprovedFM Approved
LPCBLPCB Certified
BSI KitemarkBSI Kitemark
CDAASubmittal Ready
LIFECO Verified Systems

LIFECO Engineered Systems & Hardware for Fire Safety Services

Explore verified technical specifications, pressure ratings, and system configurations. Technical cut-sheets, BOQ estimates, and consultant submittal dossiers are available on request.

NFPA 2001 & CDAA Mandatory
CDAA Compliant Submittal
Certified Door Fan Room Integrity Testing for Clean Agent Systems
Specialist Engineering Diagnostic

Certified Door Fan Room Integrity Testing for Clean Agent Systems

Model: RETROTEC / EN-15004 / NFPA 2001

Validate that your gaseous fire suppression system can hold the required agent concentration for the mandated retention time (min. 10 minutes) without releasing a single drop of agent. Certified computerized Door Fan Testing across Oman in full compliance with NFPA 2001 and ISO 14520.

Regulatory ComplianceNFPA 2001, ISO 14520, BS EN 15004, CDAA Oman Approved
Retention Hold TimeMinimum 10 minutes agent hold time validation
Test MethodologyCalibrated blower door pressurisation & depressurisation cycles
Applicable AgentsFK-5-1-12, HFC-227ea, CO₂, and Inert Gases (IG-55, IG-100, IG-541)
Report TurnaroundCertified engineering test report & leakage analysis within 24 hours
Testing Duration60 to 120 minutes non-destructive on-site procedure
Request Submittal & BOQ ↗
Specialized Diagnostic Engineering

Certified Room Integrity Testing & Enclosure Airtightness (Door Fan Test)

Mandatory under NFPA 2001 and Oman Civil Defence (CDAA) guidelines: Before commissioning clean agent or inert gas systems, enclosures must undergo computerized door fan testing to verify agent retention time (minimum 10 minutes) and prevent structural overpressurization.

Hold Time RetentionGuaranteed 10+ minute retention
Peak Pressure VentsEngineering sizing for relief dampers
CDAA Approval ReportOfficial certified handover documentation
Engineering support

Let’s discuss your project requirements.

Share your scope, drawings or BOQ with the PROOM engineering team.

Enquire now ↗