Fire Fighting & Life Safety · Oman

Gas-Based Fire Suppression Systems

Clean-agent and inert-gas protection concepts for sensitive spaces where water could damage critical assets.

Engineered for Oman

A complete, coordinated approach to gas-based fire suppression systems.

PROOM supports clients from initial consultation and site review through engineering, supply, installation, integration, testing, commissioning and ongoing technical support. The final scope is defined around verified project requirements and site conditions.

01Risk-led system design
02Coordinated emergency response
03Clear testing and commissioning
04Long-term maintenance readiness
Key capabilities

System scope

  • 01Room integrity review
  • 02Detection integration
  • 03Control panels
  • 04Discharge systems
  • 05Warning devices
Typical applications

Designed around the facility.

Applications are assessed according to occupancy, operating risk, performance objectives, existing infrastructure and required interfaces.

Server rooms↗
Data centres↗
Control rooms↗
Electrical rooms↗
Archives↗
System integration

Connected with the wider building environment.

Where required, PROOM coordinates interfaces with fire alarm, BMS, CCTV, access control, public address, HVAC, parking, hotel systems, IoT platforms and central monitoring. Final integration depends on the project design and supported system interfaces.

Delivery process

From scope to support.

  1. 01
    Consultation & site survey

    We understand the facility, risks, scope and operating requirements.

  2. 02
    Engineering & design

    We develop coordinated system concepts and technical specifications.

  3. 03
    Proposal & planning

    We align scope, resources, sequencing and commercial requirements.

  4. 04
    Supply & installation

    Our teams deliver and coordinate equipment and site works.

  5. 05
    Testing & commissioning

    We verify operation, interfaces and documented system performance.

  6. 06
    Maintenance & support

    We help protect reliability through planned and responsive support.

Maintenance & FAQs

Supporting performance beyond installation.

Can PROOM assess an existing system?+

Yes. PROOM can review available documentation, inspect site conditions and identify practical maintenance, integration, upgrade or retrofit requirements.

Can this system integrate with other building services?+

Integration is planned according to project needs, compatible interfaces and the approved cause-and-effect or control strategy.

Is maintenance support available?+

PROOM provides preventive and corrective maintenance, testing, inspections, system health checks, upgrades and Annual Maintenance Contract options.

Authorized Distribution & Engineering Supply · Sultanate of Oman

LIFECO UK · Certified Fire & Life Safety Systems

PROOM is the authorized engineering distributor for LIFECO (UK) in Oman. All equipment is factory-certified, fully supported with project submittal packages, datasheets, and compliance documentation for Oman Civil Defence (CDAA) approvals.

UL ListedUL Listed
FM ApprovedFM Approved
LPCBLPCB Certified
BSI KitemarkBSI Kitemark
CDAASubmittal Ready
LIFECO Verified Systems

LIFECO Engineered Systems & Hardware for Gas-Based Fire Suppression Systems

Explore verified technical specifications, pressure ratings, and system configurations. Technical cut-sheets, BOQ estimates, and consultant submittal dossiers are available on request.

Zero ODP · GWP < 1
UL ListedFM Approved
SUPREME-X™ FK-5-1-12 Clean Agent Fire Extinguishing System
SUPREME-X Clean Agent Series

SUPREME-X™ FK-5-1-12 Clean Agent Fire Extinguishing System

Model: SUPREME-X™ FK-5-1-12

Next-generation sustainable clean agent extinguishing system engineered for mission-critical IT, data center and electrical enclosures with zero ozone depletion potential and rapid flame knockdown.

Working Pressure360 PSI (25 Bar)
Cylinder Capacities17L, 28L, 52L, 106L, 147L, 180L, 240L, 270L, 369L, 453L
Environmental ProfileZero ODP, GWP < 1, rapid atmospheric lifetime
Standards ComplianceNFPA 2001, UL 2166, ISO 14520, CDAA Submittal Ready
Discharge TimeUnder 10 seconds total flooding
Request Submittal & BOQ ↗
Zero Residue · Rapid Action
UL ListedFM Approved
SUPREME-X™ HFC-227ea Clean Agent Fire Suppression System
SUPREME-X Clean Agent Series

SUPREME-X™ HFC-227ea Clean Agent Fire Suppression System

Model: SUPREME-X™ HFC-227ea

Electrically non-conductive gaseous clean agent system that extinguishes fires primarily through heat absorption, leaving zero residue on sensitive servers, telecommunications and control rooms.

Operating Pressure360 PSI (25 Bar)
Cylinder Range17L to 453L high-strength seamless steel
Safety LevelSafe for occupied spaces within NOAEL limits
Testing StandardNFPA 2001, UL Listed, FM Approved
Request Submittal & BOQ ↗
Natural Gases · 200 / 300 Bar
UL ListedFM Approved
SUPREME-X™ Inert Gas Extinguishing System (200 & 300 Bar)
SUPREME-X Inert Gas Series

SUPREME-X™ Inert Gas Extinguishing System (200 & 300 Bar)

Model: SUPREME-X™ Inert Gas (IG-01, IG-55, IG-100, IG-541)

High-pressure natural inert gas system using Argon, Nitrogen, or Inergen blends to extinguish fire by oxygen reduction without generating breakdown by-products or fogging.

Available AgentsIG-01 (Argon), IG-55, IG-100 (Nitrogen), IG-541 (Inergen blend)
Working Pressure200 Bar & 300 Bar options
Cylinder Capacities80 Liters & 140 Liters
Integrity VerificationRoom Integrity Door Fan Testing required
Request Submittal & BOQ ↗
NFPA 12 · Heavy Industrial
UL Listed
SUPREME-X™ Carbon Dioxide (CO₂) Fire Extinguishing System
SUPREME-X Industrial Hazards

SUPREME-X™ Carbon Dioxide (CO₂) Fire Extinguishing System

Model: SUPREME-X™ High Pressure CO₂

Heavy-duty 150-bar CO₂ total flooding and local application system engineered for unoccupied electrical transformer rooms, engine test bays, and flammable liquid hazards.

System Pressure150 Bar
Cylinder Capacity68 Liters high-pressure vessel
StandardsUL Listed Components, NFPA 12 Standard
ActuationAutomatic solenoid & manual mechanical release
Request Submittal & BOQ ↗
Specialized Diagnostic Engineering

Certified Room Integrity Testing & Enclosure Airtightness (Door Fan Test)

Mandatory under NFPA 2001 and Oman Civil Defence (CDAA) guidelines: Before commissioning clean agent or inert gas systems, enclosures must undergo computerized door fan testing to verify agent retention time (minimum 10 minutes) and prevent structural overpressurization.

Hold Time RetentionGuaranteed 10+ minute retention
Peak Pressure VentsEngineering sizing for relief dampers
CDAA Approval ReportOfficial certified handover documentation
Engineering support

Let’s discuss your project requirements.

Share your scope, drawings or BOQ with the PROOM engineering team.

Enquire now ↗